Skip to content

nVision Reference Recorder

SKU nVision

Options:

Request a quote
Availability:
in stock, call for availability

To order, contact us online, chat, or call (780) 463-9527

Monday-Thursday 730am-430pm; Friday 7am-4pm.

nVision Reference Recorder

Reference Pressure Recorder

Accurate enough to replace a deadweight tester
Rugged enough to sit in 3 feet of water
Portable enough to complete calibrations anywhere

• Gauge / Absolute Pressure Datalogger to 15 000 psi / 1000 bar / 100MPa
• Differential Pressure with up to 0.025% of reading accuracy 
• Switch, Voltage, Current, and Temperature
• 500 000 data points - 10 readings per second from 2 modules

There’s never been anything like this!

• Shift everyday wear to replaceable CPF adapter
• Displays live data graphically - no PC required
• Connects to a PC to view live readings or export to tamper proof digital records
• Compensates accuracy for temperature effects from -20 to 50°C
• Includes a calibration certificate with test data at 5 different temperatures from our A2LA accredited laboratory

  • Documentation

  • Application Notes 

    • Casing and Tubing Pressure Recording

      Using an nVision reference recorder to record casing and tubing pressure.

    • Replacing a Chart Recorder

      The nVision is quickly replacing aging equipment for recording pressure and temperature measurements.

    • Hydrostatic Pressure Testing

      The XP2i and nVision are ideal measuring and recording solutions to document pressure testing for the transmission system pipelines.

    •  

      Gas Industry Measurement

      AMETEK STC has a variety of products designed specifically for the natural gas industry.

    •  

      Creating a Signed PDF in CrystalControl

      How to create a tamper proof, signed PDF file in CrystalControl.

    • Self Signed Digital ID Set-Up

      How to set-up a digital ID which can be used to sign a tamper proof PDF document.

  • Options

      • BARO BARO Module – Converts gauge pressure measurement to the absolute scale.
    • System A
      • AHX Pump System: Includes a T-970 pneumatic hand pump (0 to 580 psi / 40 bar)
      • AXX Pump System: Includes a T-960 pneumatic hand pump (0 to 30 psi / 2 bar)
    • System B
      • BHX Pump System: Includes a T-975 pneumatic hand pump (-25 inHg to 580 psi / - 0.91 to 40 bar)
      • BXX Pump System: Includes a T-965 pneumatic hand pump (-25 inHg to 30 psi / - 0.91 to 2 bar)
    • System C
      • CHX Pump System: Includes a T-620H Hydraulic Hand Pump (0 to 5000 psi)
      • CXX Pump System: Includes a T-620 Hydraulic Hand Pump (0 to 3000 psi)
    • System D
      • DOX Pump System: Includes a P-018-CPF hydraulic screw pump (0 to 5000 psi, for use with oil)
      • DWX Pump System: Includes a P-018-CPF hydraulic screw pump (0 to 5000 psi, for use with water)
    • System E
      • EOX Pump System: Includes a P-014 hydraulic bench top pump (0 to 10 000 psi, for use with oil)
    • System F
      • FOV Pump System: Includes a T-1 hydraulic bench top pump (0 to 15 000 psi, for use with oil)
      • FWV Pump System: Includes a T-1 hydraulic bench top pump (0 to 15 000 psi, for use with water)
    • System G
      • GOX Pump System: Includes a GaugeCalHP hydraulic pressure comparator (0 to 15 000 psi, for use with oil)
      • GWX Pump System: Includes a GaugeCalHP hydraulic pressure comparator (0 to 15 000 psi, for use with water)
    • System H
      • HOX Pump System: Includes a T-975 Pneumatic Hand Pump (-25 inHg to 580 psi / - 0.91 to 40 bar) and a T-620H Hydraulic Hand Pump (0 to 5000 psi / 350 bar)
  • Accessories 

      • 5177 Magnetic Hanging Strap.
      • 5535 Soft Carrying Case; durable, padded case with separate pockets for your nVision and accessories (included).
      • 3985 Protective Boot; blue, Skydrol Resistant (included).
      • 3951 USB A to Mini USB Cable for HPC40 Series, HPC50 Series, and nVision (included)
      • 4947 64 ft (20 m) USB A female to USB A male active extension cable. WARNING: Do not use USB interface within a hazardous atmosphere.
      • 3952 Test Lead Kit; two 6’ (1.8 m) 2mm banana jack test leads with multi-purpose clip (included with MA20 module).
      • 3953 RTD Connection Kit; IP67 terminal block connector (RTD module not included).
      • 4126 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 48 in. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-1 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 13 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-3 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 20 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-5 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 26.2 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-15 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 30 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-10 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 49.2 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-11 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 80 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-12 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 75 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-13 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 30 ft. Temperature Range: -40 to 100°C (-40 to 212°F), w/ 1/2" NPT Male Spring Fitting for Thermowell.
      • 4623-14 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 12” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 30 ft. Temperature Range: -40 to 100°C (-40 to 212°F), w/ 1/2" NPT Male Spring Fitting for Thermowell.
      • 4623-17 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 12” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 50 ft. Temperature Range: -40 to 100°C (-40 to 212°F), w/ 1/2" NPT Male Spring Fitting for Thermowell.
      • 4623-18 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 12” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 100 ft. Temperature Range: -40 to 100°C (-40 to 212°F), w/ 1/2" NPT Male Spring Fitting for Thermowell.
      • 4623-19 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 100 ft. Temperature Range: -40 to 100°C (-40 to 212°F), w/ 1/2" NPT Male Spring Fitting for Thermowell.
      • 4623-16 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 10” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 48 in. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-7 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 12” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 48 in. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4491 RTD, 3-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 4 mm diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 4 m. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-20 RTD, 4-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 30 ft. Temperature Range: -40 to 100°C (-40 to 212°F), w/ 1/2" NPT Male Spring Fitting for Thermowell.
      • 4623-2 RTD, 4-wire Single, Std temp RTD, Pt/385/Class A3, 0.03% accuracy, 100 ohm, 4” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 60 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-6 RTD, 4-wire Single, Std temp RTD, Pt/385/Class A3, 0.03% accuracy, 100 ohm, 4” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 100 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-23 RTD, 4-wire Single, Std temp RTD, Pt/385/Class A3, 0.03% accuracy, 100 ohm, 150 x 6 mm diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 1500 mm. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-8 RTD, 4-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 6” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 150 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-9 RTD, 4-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 6” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 300 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-21 RTD, 4-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 4” x 1/4" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 30 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
      • 4623-22 50 ft extension for RTD probes, 4 wire.
      • 4748 RTD, 4-wire Single, Std temp RTD, Pt/385/Class B, 0.12% accuracy, 100 ohm, 6” x 3/16" diameter, 316SS probe, Spring Transition, PVC Insulated, stranded leads, Length= 100 ft. Temperature Range: -40 to 100°C (-40 to 212°F).
  • Software

    • CrystalControl

      CrystalControl – Free Software, Communicate, Configure, Data Log (nVision), and Update your nVision, HPC40, HPC50

    • FastCalXP

      FastCalXP – Calibration software that allows you to do a 10 point up and down calibration in less than 3 minutes.

    • JofraCal

      JofraCal (Free) - Calibration software for easy calibration of RTDs, thermocouples, transmitters, thermo switches, pressure gauges, and pressure switches.

    • USB Driver

      USB Driver for XP2i, nVision, and 30 Series

    • UnitCalc

      UnitCalc (Free) – Easy pressure unit calculator. Displays all conversion factors and converted units at the same time. UnitCalc also calculates Head Correction, Gravity Correction, and Air Density