Full Catalog
Level Probe Intrinsically Safe PML-C131-Exi
Jaron WolffPML-C131-Exi RANGE: from 0 m H2O...1 m H2O to 0...30 m H2O MEMBRANE: Steel 316L TYPE OF PRESSURE: Gauge CERTIFICATIONS: CSA, ATEX USED TECHNOLOGIES...
View full detailsLevel Probe Intrinsically Safe PML-C111-Exi
Jaron WolffPML-C111-Exi RANGE: from 0 m H2O...10 m H2O to 0...30 m H2O MEMBRANE: Steel 17-4PH TYPE OF PRESSURE: Gauge CERTIFICATIONS: CSA, ATEX USED TECHNOLOG...
View full detailsLevel Probe Intrinsically Safe PML-S131-Exi
Jaron WolffPML-S131-Exi RANGE: from 0 m H2O...1 m H2O to 0...30 m H2O MEMBRANE: Steel 316L TYPE OF PRESSURE: Gauge CERTIFICATIONS: CSA, ATEX USED TECHNOLOGIES...
View full detailsLevel Probe Intrinsically Safe PML-S111-Exi
Jaron WolffPML-S111-Exi RANGE: from 0 m H2O...10 m H2O to 0...30 m H2O MEMBRANE: Steel 17-4PH TYPE OF PRESSURE: Gauge CERTIFICATIONS: CSA, ATEX USED TECHNOLOG...
View full detailsPressure Transducer CTMd
Jaron WolffPressure transducer (data sheet 9821) Analogue output signal model CTMd accuracy ± 1.0% of the measuring range measuring cell / sensor ceram...
View full detailsTemperature Transducer PMT-S112-Exi - Intrinsically Safe, CSA, ATEX
Jaron WolffPMT-S112-Exi RANGE: -40°C … 200°C (-40°F … 392°F) MATERIAL: 1.4404 (316L) CERTIFICATIONS: CSA | ATEX Data sheet download Datasheet
Temperature Transducer PMT-S111-Exi - Intrinsically Safe, CSA, ATEX
Jaron WolffPMT-S111-Exi RANGE: -40°C … 200°C (-40°F … 392°F) MATERIAL: 1.4301 (304) CERTIFICATIONS: CSA | ATEX Data sheet download Datasheet
Pressure Transducer PMP-C122-Exi.2H - Intrinsically Safe, ATEX, EC79, Hydrogen Compatible
Jaron WolffPMP-C122-Exi.2H OPTIMIZED FOR: configurable online, High pressure PRESSURE-RANGE: 4 – 1.000 bar MEMBRANE: Steel 316L CELL CONSTRUCTION TYPE: with m...
View full detailsPressure Transducer PMP-C122-Exi.1H - Intrinsically Safe, CSA, EC79, Hydrogen Compatible
Jaron WolffPMP-C122-Exi.1H OPTIMIZED FOR: configurable online, High pressure PRESSURE-RANGE: 4 – 1.000 bar MEMBRANE: Steel 316L CELL CONSTRUCTION TYPE: with m...
View full detailsPressure Transducer PMP-S122-ExnA.1H - Non-sparking, CSA, EC79, Hydrogen Compatible
Jaron WolffPMP-S122-ExnA.1H OPTIMIZED FOR: high pressure, agressive media like Hydrogen PRESSURE-RANGE: 4 – 1.000 bar MEMBRANE: Steel 316L CELL CONSTRUCTION T...
View full detailsPressure Transducer PMP-S122-Exi.2H - Intrinsically Safe, ATEX, EC79, Hydrogen Compatible
Jaron WolffPMP-S122-Exi.2H OPTIMIZED FOR: high pressure, aggressive media like Hydrogen PRESSURE-RANGE: 4 – 1.000 bar MEMBRANE: Steel 316L CELL CONSTRUCTION T...
View full detailsPressure Transducer PMP-S122-Exi.1H - Intrinsically Safe, CSA, EC79, Hydrogen Compatible
Jaron WolffPMP-S122-Exi.1H OPTIMIZED FOR: high pressure, agressive media like Hydrogen PRESSURE-RANGE: 4 – 1.000 bar MEMBRANE: Steel 316L CELL CONSTRUCTION TY...
View full detailsPressure Transducer CTMcFB
Jaron WolffPressure transducer (data sheet 9820.3) Analogue output signal Capacitive pressure transmitter models CTMcFB are suitable for overpressure and abso...
View full detailsPressure Transducer CTMc
Jaron WolffPressure transducer (data sheet 9820) Analogue output signal Pressure transmitter models PTMFB are suitable for overpressure and absolute pressure ...
View full detailsPressure Transducer PTMFB
Jaron WolffPressure transducer (data sheet 9810.3) Analogue output signal Pressure transmitter models PTMFB are suitable for overpressure and absolute pressur...
View full detailsPressure Transducer DTMFB
Jaron WolffPressure transducer (data sheet 9810.1) Analogue output signal model DTMFB accuracy better than ± 0.5 % special equipment measuring cell wel...
View full detailsPressure Transducer DTMk
Jaron WolffPressure transducer (data sheet 9830.1) Analogue output signal model DTMk accuracy better than ± 0.5 % special equipment measuring cell weld...
View full detailsPressure Transducer PTMv
Jaron WolffPressure transducer (data sheet 9810.2) Analogue output signal model PTMv accuracy better than ± 0.5 % special equipment measuring cell weld...
View full detailsPressure Transducer PTM
Jaron WolffPressure transducer (data sheet 9810) Analogue output signal model PTM accuracy better than ± 0.5 % measuring cell / sensor piezoresistive s...
View full detailsPressure Transducer DTM
Jaron WolffPressure transducer (data sheet 9830) Analogue output signal model DTM accuracy better than ± 0.5 % special equipment measuring cell welded ...
View full detailsPressure Transducer PMP-C131-Exi - Intrinsically Safe, CSA, ATEX
Jaron WolffPMP-C131-Exi Intrinsically safe pressure transducer OPTIMIZED FOR: configurable online, low pressure, aggressive media PRESSURE-RANGE: 20 mbar – 1...
View full detailsPressure Transducer PMP-C122.04-ExD - Explosion Proof, CSA, Hydrogen Compatible
Jaron WolffPMP-C122.04-ExD Explosion Proof / Flameproof Enclosure Pressure Transducer OPTIMIZED FOR: configurable online, high pressure, aggressive media like...
View full detailsPressure Transducer PMP-C122-Exi - Intrinsically Safe, CSA, ATEX, EC79, Hydrogen Compatible
Jaron WolffPMP-C122-Exi Intrinsically safe pressure transducer OPTIMIZED FOR: configurable online, high pressure, aggressive media like Hydrogen PRESSURE-RAN...
View full detailsPressure Transducer PMP-C111-Exi - Intrinsically Safe, CSA, ATEX
Jaron WolffPMP-C111-Exi Intrinsically safe pressure transducer OPTIMIZED FOR: configurable online, high pressure, fast temperature changes, aggressive medias ...
View full detailsPressure Transducer PMP-S131-Exi - Intrinsically safe, CSA, ATEX
Jaron WolffPMP-S131-Exi Intrinsically safe pressure transducer OPTIMIZED FOR: Low pressure, aggressive media PRESSURE-RANGE: 60 mbar – 10 bar MEMBRANE: Stee...
View full detailsPressure Transducer PMP-S122.04-ExD - Explosion Proof, CSA, Hydrogen Compatible
Jaron WolffPMP-S122.04-ExD Explosion Proof / Flameproof Enclosure Pressure Transducer OPTIMIZED FOR: High pressure, aggressive media like Hydrogen PRESSURE-R...
View full detailsPressure Transducer PMP-S122-Exi - Intrinsically Safe, CSA, ATEX, EC79, Hydrogen Compatible
Jaron WolffPMP-S122-Exi Intrinsically safe pressure transducer OPTIMIZED FOR: High pressure, aggressive media like Hydrogen PRESSURE-RANGE: 4 – 1.000 bar ME...
View full detailsPressure Transducer PMP-S122-ExnA - Non-sparking, CSA, Hydrogen Compatible
Jaron WolffPMP-S122-ExnA Non-sparking pressure transmitter OPTIMIZED FOR: High pressure, aggressive media like Hydrogen PRESSURE-RANGE: 4 – 1.000 bar MEMBRA...
View full detailsPressure Transducer PMP-S111-ExnA - Non-sparking, CSA
Jaron WolffPMP-S111-ExnA Non-sparking pressure transmitter OPTIMIZED FOR: High pressure, fast temperature changes, aggressive media PRESSURE-RANGE: 3 – 2.000...
View full detailsPressure Transducer PMP-S111-Exi - Intrinsically Safe, CSA, ATEX
Jaron WolffPMP-S111-Exi Intrinsically safe pressure transducer OPTIMIZED FOR: High pressure, fast temperature changes, aggressive media PRESSURE-RANGE: 3 – 2...
View full details